Black Box 3600 Manuel D’Utilisation

Page de 270
Status Registers
Modem 3600
10-11
DTR State Recognition    S25
The S25 register specifies the amount of time (0-255) in 0.01 second 
(10 ms) increments that DTR must stay high or low in order to be 
recognized as such. The default value is 5 (0.05 second).
RTS/CTS Delay    S26
The S26 register specifies the amount of time (0-255) in 0.01 second 
(10 ms) increments between the RTS signal and the CTS signal. The 
default value is 0.
Bit Mapped   S27
Lookback Timer    S28
The S28 register specifies the amount of time in 1.0 minute increments 
that the modem will remain in dial backup mode before retrying leased 
line mode. A zero will disable automatic lookback to leased line. The 
default value is 15 minutes. 
Bit
Value
Command Description
1, 0
00
01
10 
11
&M
&M1
&M2
&M3
Async
Sync data / async dial
Sync data / dial through DTR 
Sync data / manual dial
2
0
1
&L
&L1
 and 
&L2
Dial-up line 
Leased line
3
--
--
Reserved
5, 4
00 
01
10
11
&X
&X1
&X2
--
Internal clock
External clock
Receive clock
Not used
6
1
0
--
Enable async DTR dialer
Disable async DTR dialer
7
--
--
Reserved
Bit
Value
Command Description
7- 0 0-255
--
Time in 1 minute increments (0=disabled)