Black Box 3600 MODEM Manuel D’Utilisation

Page de 270
Hardware Options
Modem 3600
D-3
Part II
This part determines the performance of the local and remote modems 
and the telephone circuits. It also determines each modem's ability to 
receive a transmitted signal from the other site, properly equalize and 
decode the signal and then loop this regenerated signal into the 
transmitter for transmission back to the other modem. This test applies 
to both leased line and dial line operation.
1) Configure the local modem for REMOTE DIGITAL LOOP 
WITH TEST PATTERN. This signals the remote modem to go 
into digital loop. The remote modem receives and then 
retransmits the data back to the local mode. If the digital bilateral 
loop is enabled at the remote, the remote DTE is looped back to 
itself.
2) An alternative to the above procedure is to request the operator at 
the remote modem to configure his modem for LOCAL 
DIGITAL LOOP. Configure the local modem for TEST 
PATTERN. The remote modem receives and retransmits the data 
back to the local modem.
3) The TEST PATTERN ERRORS display will count received 
errors.
4) At the local modem, the indicators should be as follows:  
5) To further test the modem and communications link, reverse the 
system loopback. First exit the existing loopback test. Reverse 
the roles of the local and remote modems and repeat step two.
Note
If the bilateral digital loop is enabled at the local modem, the 
DTE interface is looped to itself and permits the DTE to 
check the interface circuitry as well as itself.