ASUS P8H61MLXPLUSR20 Manuel D’Utilisation

Page de 68
2-24
ASUS P8H61-MX Series
2.6.5 
Chassis Q-Fan Control [Enabled]
[Disabled] 
Disables the Chassis Q-Fan control feature.
[Enabled] 
Enables the Chassis Q-Fan control feature.
Chassis Fan Speed Low Limit [600 RPM]
This item appears only when you enable the Chassis Q-Fan Control feature and 
allows you to disable or set the chassis fan warning speed. Configuration options: 
[Ignore] [200RPM] [300 RPM] [400 RPM] [500 RPM] [600 RPM]
Chassis Fan Profile [Standard]
This item appears only when you enable the Chassis Q-Fan Control feature and 
allows you to set the appropriate performance level of the chassis fan.
[Standard] 
Sets to [Standard] to make the chassis fan automatically adjust 
depending on the chassis temperature.
[Silent] 
Sets to [Silent] to minimize the fan speed for quiet chassis fan 
operation.
[Turbo] 
Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] 
Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set Chassis Fan Profile to [Manual].
Chassis Upper Temperature [70]
Use the <+> and <-> keys to adjust the upper limit of the CPU temperature. The values range 
from 40ºC to 90ºC. 
Chassis Fan Max. Duty Cycle(%) [100]
Use the <+> and <-> keys to adjust the maximum chassis fan duty cycle. The values range 
from 60% to 100%. When the chassis temperature reaches the upper limit, the chassis fan will 
operate at the maximum duty cycle.
Chassis Lower Temperature [40]
Displays the lower limit of the chassis temperature.
Chassis Fan Min. Duty Cycle(%) [60]
Use the <+> and <-> keys to adjust the minimum chassis fan duty cycle. The values range from 
60% to 100%. When the chassis temperature is under 40ºC, the chassis fan will operate at the 
minimum duty cycle.
2.6.6 
Anti Surge Support [Enabled]
This item allows you to enable or disable the Anti Surge function.
Configuration options: [Disabled] [Enabled]