American Dynamics KT-400 Manuel D’Utilisation

Page de 44
DN1726-0811
34
Configuring the KT-400 Ethernet Four-Door Controller with the KT-Finder 
(continued)
 7. Put jumpers on JP2 and JP3.
 8. Verify your Network Configuration Information Sheet:
Enter the EntraPass IP address or the Domain name of the EntraPass Gateway. This information must be the same 
as entered in EntraPass workstation for Devices > Site.
Select Obtain an IP address automatically or Use the following IP address. This information must be the same as 
entered in EntraPass workstation for Devices > Site.
 9. Change the Port number, if required.
Note:  The port number should only be changed when you have more than one KT-400 at the same remote site.
 10.Click OK.
 11. Repeat the procedure for each KT-400 at this site.