ATTO Technology SC 5700 Manuel D’Utilisation

Page de 73
viii
DriveTest 
Starts or stops a drive test with the previously-specified 
configuration and drive list. Drives which are in-use by the test 
are not available for RAID configuration or RAID operations. 
Only one test can be run at a time.
DriveTest [Begin | Cancel]
DriveTestConfig
Configures the next drive test to perform: initialize (destructive 
write-only), read (non-destructive read-only), verify (destructive 
verify), or init-verify (destructive write-read-verify).The test is not 
started until the 
 Begin command is given.
set DriveTestConfig [init | read | verify | init-verify]
get DriveTestConfig
DriveTestList
Specifies drives to be run in the next drive test. This command 
can be called with different eligible block IDs and each one is 
added to the list. Drives which are not part of a RAID group or 
are not hot spares are eligible. The all parameter automatically 
chooses eligible drives. The test is not started until the 
Begin command is given.
set DriveTestList [drive [BlockDevID] | all]
get DriveTestList
DriveTestStatus
Displays the status of the currently running drive test, but does 
not display performance metrics. If a block device ID is not 
running or cannot be found, its state is idle and percent 
complete is 0.
get DriveTestStatus <drive [BlockDevID]>
DumpConfiguration
Displays the unit’s configuration to the Advanced page of the 
ExpressNAV Storage Manager or a terminal emulation or telnet 
session. The record may not be displayed completely in the 
ExpressNAV page.
DumpConfiguration
DumpEventLog 
Displays the contents of the 
 to the Advanced page 
of the ExpressNAV Storage Manager or a terminal emulation or 
telnet session. The record may not be displayed completely in 
the ExpressNAV page.
DumpEventLog
EmailFromAddress
Configures the Email address that the unit uses to communicate 
with the Email server. Full Email address is a fully qualified 
Internet Email address, not more than 128 characters long.
set EmailFromAddress [full email address]
get EmailFromAddress
EmailNotify
Regulates Email notification. 
Default: disabled.
set EmailNotify [enabled | disabled]
get EmailNotify
EmailNotifyAddress
Configures notification addresses. Index is a number between 1 
and 5. Full Email address is a fully qualified Internet Email 
address, not more than 128 characters long. Emails are sent 
based on the warning level you set to trigger an Email alert.
Warning levels
None: no Emails 
Critical: only critical severity events
Warning: warnings and critical events
Informational: information
All: all warnings, critical events and informational 
messages
set EmailNotifyAddress [index] [full email address] 
[warning level]
get EmailNotifyAddress <index | all>
EmailPassword
Configures the password which authenticates the login to the 
SMTP Email server. The password must not be more than 64 
characters. A password is not required if the Email server does 
not require authentication.
set EmailPassword
SaveConfiguration command required
EmailServerAddress
Configures the address of the server the unit must contact in 
order to send out Email notifications using either an Email 
address (xxx.xxx.x.x) or a fully qualified domain name 
(mal.myserver.com).
Default: 0.0.0.0
set EmailServerAddress [IP address |domain name]
SaveConfiguration command required
get EmailServerAddress
EmailUsername
Configures the user name which authenticates the login to the 
SMTP Email server. The user name must not be more than 128 
characters. A user name is not required if the Email server does 
not require authentication.
set EmailUsername [username]
SaveConfiguration command required
get EmailUsername