Compaq HSZ80 Array Controller ACS Version 8.3 Configuration and CLI Reference Guide
Follow these steps to configure a controller:
NOTE:  This procedure has been written for first-time configuring. However, you 
can adapt the procedure when you reconfigure the controllers. For replacing and 
upgrading the controllers, see the 
HSZ80 Array Controller ACS Version 8.3 
Maintenance and Service Guide.
1.
Use the power-verification and addressing (PVA) module ID switch to set the 
SCSI ID number for the BA370 rack-mountable enclosure.
See “Setting the PVA Module ID Switch,” page 2–25, for details about PVA switch 
settings.
2.
Remove the program card ESD cover, and insert the program card into the 
controller. Replace the ESD cover. Repeat for the other controller.
3.
Turn on the power to the enclosure or cabinet by turning on the ac input boxes.
4.
Establish a local connection to the controllers.
Table 2–3  Location of Parts for Multiple-Bus Failover 
Item
Description
Host port 1
Host port 2
Trilink connector
Host bus cable
Ferrite bead
Terminator