Seagate ST31000533CS Manuel D’Utilisation

Page de 44
12
Pipeline HD Pro Serial ATA Product Manual, Rev. C
2.9
Acoustics
Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). All mea-
surements are consistent with ISO document 7779. Sound power measurements are taken under essentially 
free-field conditions over a reflecting plane. For all tests, the drive is oriented with the cover facing upward.
Note. For seek mode tests, the drive is placed in seek mode only. The number of seeks per second is defined 
by the following equation: 
 
 
(Number of seeks per second = 0.4 / (average latency + average access time)
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and 
power to operational levels.
2.9.1
Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this 
process is the use of the absolute threshold of hearing. Seagate uses this threshold curve (originated in ISO 
389-7) to discern tone audibility and to compensate for the inaudible components of sound prior to computation 
of tone ratios according to Annex D of the ECMA-74 standards.
2.10
Electromagnetic immunity
When properly installed in a representative host system, the drive operates without errors or degradation in 
performance when subjected to the radio frequency (RF) environments defined in the following table:
Table 3: 
Fluid Dynamic Bearing (FDB) motor acoustics
Idle*
CE Seek
1000 GB model
2.9 bels (typ)
 
3.1 bels (max)
3.1 bels (typ)
 
3.2 bels (max)
Table 4: 
Radio frequency environments
Test
Description
Performance level
Reference standard
Electrostatic 
discharge
Contact, HCP, VCP: ± 4
 
kV; Air:
 
± 8 kV
B
EN 61000-4-2: 95
Radiated RF 
immunity
80 to 1,000 MHz, 3 V/m, 
 
80% AM with 1 kHz sine
 
900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz
A
EN 61000-4-3: 96
 
ENV 50204: 95
Electrical fast 
transient
± 1 kV on AC mains, ± 0.5 kV on external I/O
B
EN 61000-4-4: 95
Surge immunity
± 1 kV differential, ± 2 kV common, AC mains
B
EN 61000-4-5: 95
Conducted RF 
immunity
150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A
EN 61000-4-6: 97
Voltage dips, 
interrupts
0% open, 5 seconds
 
0% short, 5 seconds
 
40%, 0.10 seconds
 
70%, 0.01 seconds
C
 
C
 
C
 
B
EN 61000-4-11: 94