Panasonic WJ-GXE900 Manuel D’Utilisation

Page de 119
83
Symptom
Possible cause / Possible solution
Reference page
• Are "RECEIVING IP ADDRESS" and "RECEIVING
PORT No." of the decoder set correctly to receive
streaming video and audio data?
Check "DESTINATION IP ADDRESS" and
"DESTINATION PORT No." on the VIDEO page of
the encoder, and set the same values for
"RECEIVING IP ADDRESS" and "RECEIVING
PORT No." of the decoder.
To confirm temporarily, click the [START] button
after entering a value on the CONTROL/STATE
page of the decoder.
The image is not
displayed while the
STATUS 1 - 4 indicators of
the encoder are lit and the
STATUS 1 - 4 indicators of
the decoder are blinking.
44, 68, 69
• Are there noise influences caused by power grounding,
case grounding or cable shield wear?
When not using groundings or shielded cables (STP
cable, etc.), noise influences may easily occur.
Use groundings or shielded cables.
The image is not displayed
while the STATUS 1 - 4
indicators of the both the
encoder and decoder are lit.
• The encoder may be down.
Check the status of the encoder on the CONTROL/STATE
page. When the status is "STOP", click the [START] button.
The STAUS 1 - 4
indicators of the encoder
are not lit.
43
• The decoder may be down.
Check the status of the decoder on the CONTROL/
STATE page. When the status is "STOP", click the
[START] button.
The image is not
displayed while the
STATUS 1 - 4 indicators of
the decoder are not lit.
68
• Is the monitor connected correctly?
Confirm that the monitor is connected to the VIDEO OUT
connector of the decoder.
15
• Is the encoder/decoder installed in a place subject to
high-frequency noise?
When installed near fluorescent lamps, a transfor-
mer or a CRT monitor, it may have influences by
high-frequency noise. In this case, install the
encoder/decoder away from such devices.
The image is not
displayed correctly.
• Are the cables connected to the encoder/decoder wired
along with high-voltage power cables, etc.?
When the cables are wired within 10 cm from high-voltage
power cables, etc., there might be noise influences.
Wire the cables more than 10 cm away from high-voltage
power cables, etc. or wire them separately.