National Instruments SCXI-1121 Manuel D’Utilisation

Page de 162
Appendix E
SCXI-1121 Cabling
E-10
www.natinst.com
Figure E-3.  SCXI-1180 Front Panel Installation
SCXI-1302 50-Pin Terminal Block
The SCXI-1302 terminal block has screw terminal connections for the 
50-pin connector on the SCXI-1180 feedthrough panel.
SCXI-1302 Wiring Procedure
To wire the SCXI-1302 terminal block, you must remove the cover, connect 
all the wiring, and replace the cover. The procedure for this is as follows:
1.
Unscrew the rear grounding screw on the back of the terminal block, 
as shown in Figure E-4.
2.
With a flathead screwdriver, carefully pry the cover off the terminal 
block. 
3.
Insert each wire through the terminal block strain-relief opening.
4.
Connect the wires to the screw terminals.
5.
Tighten the large strain-relief screws to secure the wires.
Front Panel 
Connector
Front Panel
Front Threaded Strip
Ribbon Cable to 
Rear and Breakout 
Connectors
Step 5