Omega Vehicle Security 1500 Manuel D’Utilisation

Page de 256
Registers, Data Formats, & Queries
Appendix D
D-8 
NetScan User’s Manual
 
Binary Data Format
 
Only High/Low/Last (HLL) register and acquisition output data, may be in binary format.  Binary formatted data
can be output in either highbyte/lowbyte or lowbyte/highbyte format.
 
 
Time/Date Stamp
 
If binary format is selected, the High/Low/Last register values will also include time/date stamps.  When
outputting the High/Low/Last registers for either highbyte/lowbyte or lowbyte/highbyte, the time/date stamp will
have the following format:
 
 
hmstMDY
 
 
where each letter is a byte represented by:
 
 
h
 
hours
 
 
M
 
months
 
m
 
minutes
 
 
D
 
days
 
s
 
seconds
 
 
Y
 
years
 
t
 
tenths
 
 
 
 
 
A typical High/Low/Last will have the following binary format (each letter is a byte of data):
 
HHhmstMDYLLhmstMDYll
where: 
HH
 is high, 
LL
 is low, and 
ll
 is last
 
 
Counts Data Format
 
The Counts data format is a format that is characterized by an ASCII integer number from -32676 to +32676
that represents a compensated or raw value as it would be interpreted from the A/D converter.  This value would
be dependent upon the channel type which has been specified for the channel in question.
 
 
Note: The Counts format closely follows the channel type that has been specified.
 
 
Example 1:
 
If channel 16 was type 1: (Type J TC with cold junction compensation and linearization) then the
Counts format output value for this channel would also be cold junction compensated and linearized.
 
 
Example 2:
 
If channel 16 was type 31: (Raw A/D data), then the Counts format output value for channel 16 would
also be raw.
 
 
Both temperature and volts readings will be represented by a bipolar 16-bit value of the form: +
xxxxx
.
Time/Date stamp format is 
hmstMDY
, which is
 
the same as that specified for the binary data format.
 
The Counts format is both a valid input (C and L command) format and a valid output format (R, R#, U4, U5,
U8