Omega Vehicle Security ISA RS-422 Manuel D’Utilisation

Page de 25
 
Card Setup 
OMG-ULTRA-SIO 
Page 8 
Line Termination 
Typically, each end of the RS-485 bus must have line terminating resistors (RS-
422 terminates at the receive end only). A 120 ohm resistor is across each RS-
530/422/485 input in addition to a 1K ohm pull-up/pull-down combination that 
bias the receiver inputs. Headers E1 and E4 allow the user to customize this 
interface to their specific requirements. Each jumper position corresponds to a 
specific portion of the interface. If multiple  OMG-ULTRA-SIO  adapters are 
configured in a RS-485 network, only the boards on each end should have 
jumpers T, P & P ON. Refer to the following table for each position’s operation: 
 
Name 
Function 
Connects the TX+ to RX+ for RS-485 two wire operation. 
Adds or removes the 120 ohm termination. 
Connects the TX- to RX- for RS-485 two wire operation. 
Adds or removes the 1K ohm pull-down resistor in the 
RS-422/RS-485 receiver circuit (Receive data only). 
Adds or removes the 1K ohm pull-up resistor in the RS-422/RS-
485 receiver circuit (Receive data only).  
 
L
T
L
P
P
 
Figure 10 - Headers E1 and E4, Line Termination