Appendix A - Troubleshooting 
OMG-ULTRA-SIO 
Page 12 
Appendix A - Troubleshooting 
Serial Utility test software is supplied with the adapter and will be used in the 
troubleshooting procedures. By using this software and following these simple 
steps, most common problems can be eliminated without the need to call 
Technical Support. 
1. 
Identify all I/O adapters currently installed in your system. This includes 
your on-board serial ports, controller cards, sound cards etc. The I/O 
addresses used by these adapters, as well as the IRQ (if any) should be 
identified. 
2. 
Configure your adapter so that there is no conflict with currently installed 
adapters. No two adapters can occupy the same I/O address.  
3. 
Make sure the adapter is using a unique IRQ The IRQ is typically selected 
via an on-board header block. Refer to the section on Card Setup for help in 
choosing an I/O address and IRQ. 
4. 
Make sure the adapter is securely installed in a motherboard slot. 
5. 
When running DOS, Windows 3.x or other operating systems refer to the 
Serial Utilities software for that operating system and the User Manual to 
verify that the adapter is configured correctly. The supplied software 
contains a diagnostic program 'SSD' that runs under DOS and will verify if an 
adapter is configured properly. This diagnostic program is written with the 
user in mind and is easy to use. Refer to the DIAG.txt file in the dos\diag 
directory for detailed instructions on using 'SSD'. 
6. 
For Windows 95/98 and Windows NT, the diagnostic tool 'WinSSD' is 
installed in the Omega Engineering folder on the Start Menu during the 
setup process. First find the ports using the Device Manager, then use 
'WinSSD' to verify that the ports are functional. 
7. 
Always use the diagnostic software when troubleshooting a problem. This 
will help eliminate any software issues and identify any hardware conflicts.