Configuring ISDN BRI hardware
Note 1: Power Source 1 (PS1): Up to 2 Watts of power is supplied by
the SILC to the terminals on the DSL. This power is simplexed over the
TX and RX pairs provided by -48 V (-40 V for Europe) supply on the
SILC. The RX pair is positive with respect to the TX pair.
Note 2: Power Sink 2 (PS2) provides an optional means of powering
the terminal from a common supply in the wiring closet.
Note 3: Power Source 3 (PS3) provides the power from the terminal to
the NT1 if the NT1 does not have a local power source.
U interface specification
The U interface uses a 2-conductor, twisted pair cable terminated with
an RJ-45 type jack. An RJ-45 type jack on the NT1 device connects the
terminal to the DSL using this twisted pair cable.
The connector pin assignments for the jack and the plug are shown in
. The table also shows
signal names for each interface pin at the UILC and at the terminal.
Table 18
U interface connector specification
Pin number
RJ45 jack
pin signal name
UILC
signal name
1
Not used
No connection
2
Not used
No connection
3
Not used
No connection
4
Tip or Ring
Tip or Ring
5
Tip or Ring
Tip or Ring
6
Not used
No connection
7
Not used
No connection
8
Not used
No connection
Procedure 23
Connecting the ISDN BRI terminals to the DSL
Step
Action
1
Plug one end of the modular cable into the ISDN BRI interface
connector on the terminal. Plug the other end of the modular cable
into the telephone outlet.
2
If the SILC S/T interface has an optional auxiliary power source,
plug the power source into the wall outlet and then the 10-m (33-ft)
modular cable into the power source’s RJ-45 type jack.
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318
01.02
Standard
Release 5.0
20 June 2007