Nortel Networks R2MFC Manuel D’Utilisation

Page de 114
45
R2MFC Media Bay Module Installation and Configuration Guide
Chapter 5
Configuring the R2MFC MBM
Trunk protocol conversion provides interworking between two different trunk protocols, and 
requires configuration for the following: 
E1- MFCR2
E1- ETSI Euro-PRI
The MFCR2 is the external interface. The external interface connects to a public network. The 
R2MFC MBM contains preprogrammed country-specific MFCR2 settings that can be selected 
using the DIP switches on the faceplate of the R2MFC MBM. The MFCR2 settings can also be 
customized. The PRI is an internal link to the BCM. The PRI setting are configured to predefined 
settings when the region is selected during BCM initialization. The PRI does not require 
customization, but it must be configured as detailed in 
.
This chapter lists the configurable parameters of both the MFCR2 side and the PRI side of the 
R2MFC MBM, and explains how to configure them. 
 provides an overview of the 
configuration process.
Figure 16   Configuring the R2MFC MBM 
Install the
R2MFC MBM
Does the
setup require custom
settings?
NO
YES