Nortel Networks R2MFC Manuel D’Utilisation

Page de 114
Chapter 5 Configuring the R2MFC MBM 53
R2MFC Media Bay Module Installation and Configuration Guide
Select the appropriate Bus # under Configuration > Resources > Telephony Resources in 
the navigation tree.
The Bus # information frame displays. See 
 for an example of the screen layout for 
an R2MFC MBM configured on Bus 2.0.
Figure 19   BCM Bus configuration for R2MFC MBM
Configure the fields in the Details for Module: 2.0 panel. See 
settings.
Table 7   Module configuration parameters
Parameter
Setting
Trunk type
PRI
Protocol
Euro
Clock source
Primary external (if only one 
trunk module in system; 
otherwise, it depends on the 
synchronization scheme of 
the BCM)
Overlap receiving
Selected (On)
Local number length
According to BCM local 
dialing plan (customer - 
dependent)
Note: This field appears 
only when the Overlap 
receiving field is selected.
E1 Parameters - CRC4
Not Selected (Off)