98
Configuring DIP switch settings and definitions
NN40010-300
Brazil Config 1
E1 physical characteristics
Connector type: BNC
Line coding: HDB3
E1 framing
Frame mode: Alternate
Register signaling
Regret option: ON
End of dialing (Incoming): 4
End of dialing (Outgoing): 4
R2 line signaling
Brazil Config 1 R2 signals are according to CCITT standard. See 
 for the Brazil Config 1 
R2 signal definitions. 
Note: CD bits are not used. They are set to 01 in transmit direction, and are ignored in receive direction.
MFC Register Signaling
MFC signal definitions depends on the stage and the direction of the call; there are four tables of 
15 signals each: the first stage uses I signals forward and A signals backward, and the second stage 
uses II signals forward and B signals backward. The meaning of the signals can also be different 
when being transmitted or received. Meanings of the MFC signals are configurable. MFC signal 
tables are part of the country-specific parameters.
Table 34   Brazil Config 1 R2 A/B signals
Forward
Backward
Signal
A
B
Signal
A
B
Idle
1
0
Idle
1
0
Seize
0
0
Seize acknowledge
1
1
Clear forward
1
0
Answer
0
1
Clear back
1
1
Block
1
1