Nortel Networks Option 11C Manuel D’Utilisation

Page de 546
NT8D14 Universal Trunk Card
Page 383 of 544
Environmental specifications
Table 116 lists the environmental specifications for the Universal Trunk 
Card.
Foreign and surge voltage protection
The Universal Trunk Card meets CS03 overvoltage (power cross) 
specifications.
Release control
Release control establishes which end of a call (near, far, either, joint, or 
originating) disconnects the call. Only incoming trunks in idle ground start 
configuration can provide disconnect supervision. You configure release 
control for each trunk independently in the Route Data Block (LD 16).
PAD switching
The transmission properties of each trunk are characterized by the class-of-
service (COS) you assign in the Trunk Data Block (LD 14). Transmission 
properties may be via net loss (VNL) or non via net loss (non-VNL).
Non-VNL trunks are assigned either a Transmission Compensated (TRC) or 
Non-Transmission Compensated (NTC) class-of-service to ensure stability 
and minimize echo when connecting to long-haul trunks, such as Tie trunks. 
The class-of-service determines the operation of the switchable PADs 
contained in each unit. They are assigned as follows:
Transmission Compensated
— used for a two-wire non-VNL trunk facility with a loss of greater 
than 2 dB for which impedance compensation is provided
Table 116
Environmental specifications
Parameter
Specifications
Operating temperature
0 to 50 degrees C, ambient
Operating humidity
5 to 95% RH (non-condensing)
Storage temperature
- 40 to + 70 degrees C