Delta Electronics LCP-1250B4QDRx Manuel D’Utilisation

Page de 13
 
 
DELTA ELECTRONICS, INC.
 
2 2008/1/23
Rev. 6G
www.deltaww.com
 
Absolute Maximum Ratings 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Storage Temperature 
Ts 
-40 
 
85 
ºC 
 
Supply Voltage 
V
CC
 0    5  V 
 
Recommended Operating Conditions 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Case Operating Temperature 
T
C
 -5 
  70 
ºC 
Supply Voltage 
V
CC
 3.135
  3.465
 
Relative Humidity (non condensation) 
 
85 
 
Note 1: See order information
 
Electrical Characteristics 
(V
CC
=3.3V 
± 5%) 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Total Supply Current 
I
CCT
    300 mA 
 
Transmitter 
Transmitter Differential Input Voltage 
V
DT
 
0.5  2.4  V 
Transmitter Disable Input-High 
V
DISH
 2   
V
CC
+0.3
V  
Transmitter Disable Input-Low 
V
DISL
 0    0.8  V 
 
Transmitter Fault Pull up Resistor 
R
TX_FAULT
4.7   10  kΩ 2 
Transmitter Fault Output-High 
V
TXFH
 2   
V
CC
+0.3
V 2 
Transmitter Fault Output-Low 
V
TXFL
 0    0.8  V 
Receiver 
Receiver Differential Output Voltage 
V
DR
 0.35   
Receiver LOS Load 
R
RXLOS
 4.7 
 
10 
kΩ 2 
LOS Output Voltage-High 
V
LOSH
 2   
V
CC
+0.3
V 2 
LOS Output Voltage-Low 
V
LOSL
 0    0.8  V 
Output Data Rise/Fall Time 
t
/ t
f
  220  psec  4 
 
Notes: 
1.  Internally AC coupled and terminated to 100Ohm differential load. 
2.  Pull up to V
CC
 on host Board 
3.  Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/ 
Deserializer. 
4.  These are 20%~80% values