Magma EBU Manuel D’Utilisation

Page de 77
M A G M A  
            17  
For example, below is showing the Magma Chassis on Bus 7, Device 0, 
Function 0. Some information has been deleted, but notice the Link 
Supported Speed is 2.5 Gb/s, Width x8 . This is helpful to know that the 
chassis is configured for x8 PCI Express Speeds highlighted in red. 
07:00.0 PCI bridge: Integrated Device Technology, Inc. 
Unknown device 8037 (prog-if 00 [Normal decode]) 
 
Control: I/O+ Mem+ BusMaster+ SpecCycle- MemWINV-  
 
Status: Cap+ 66MHz- UDF- FastB2B- ParErr-
 
Latency: 0, Cache Line Size: 64 bytes 
 
Device: MaxPayload 256 bytes, MaxReadReq 128 bytes 
 
Link: Supported Speed 2.5Gb/s, Width x8, ASPM L0s 
L1, Port 0 
 
Link: Latency L0s <512ns, L1 <4us 
 
Link: ASPM Disabled CommClk+ ExtSynch- 
 
Link: Speed 2.5Gb/s, Width x8 
 
Capabilities: [c0] Power Management version 3 
 
Flags: PMEClk- DSI- D1- D2- AuxCurrent=0mA 
PME(D0+,D1-,D2-,D3hot+,D3cold+) 
 
Status: D0 PME-Enable- DSel=0 DScale=0 PME- 
 
Capabilities: [100] Advanced Error Reporting 
 
Capabilities: [200] Virtual Channel 
 
 
IMPORTANT ORDER OF PCI EXPRESS SLOTS 
The PHYSICAL PCI Express Slots 1 – 7 are not 
in order when displayed in any Operating 
Systems Device information.   
 
 
 
Mapping Physical Slot locations to port locations using lspci 
How do you locate your PCI Express Devices in our Magma Chassis? 
And how does that correspond to physical slot locations? 
Below is an example of 7 PCI Express Downstream Ports in our Magma 
Chassis. This output comes from lspci –vvv > info.txt. It has been 
cleaned up for this example. The Magma Chassis is located below 
under Bus 07. There are 7 downstream ports on Bus 8, each port has a 
number starting with 2, 4, … up to 14. Each port is associated with a 
physical slot number, 1 through 7. Ultimately, there is a SCSI card 
below located on port 8, port 8, corresponding to physical slot 2. 
Unfortunately, the SCSI card results from lspci do not spell out SLOT 2
just port 8 and that is why it is important to understand that a 
downstream port number is not the same as a physical slot number. 
The Ethernet card is on port 14, corresponding to physical slot 7.