Emerson CC1000DM Manuel D’Utilisation

Page de 64
P M C / P C I   I N T E R F A C E
PMC Module Installation
3-2
3
2
To prevent ESD damage to the CC1000dm carrier card and the PMC modules, wear a grounding 
wriststrap and use a grounded work surface while handling the card.
3
Set up the PMC module and install it on the CC1000dm carrier card as specified in the module’s 
hardware manual.
Mo na rc h F un c t i o na l i t y   
Each slot (PMC1 and PMC2) on the CC1000dm carrier card can be configured to func-
tion as either a Monarch or non-Monarch PMC slot (in non-transparency or legacy 
mode), as described in the Processor PMC Standard for Processor PCI Mezzanine Cards, 
VITA 32- 2003 Specification
. Although only one slot can be a Monarch, there can be 
as many non-Monarch PMCs as the carrier card can support. A module placed on the 
Monarch slot performs local PCI bus enumeration and handles PMC interrupts. A mod-
ule placed on the non-Monarch slot behaves in the traditional slave processor manner. 
Both slots have the ability to be configured as either Monarch or non-Monarch by the 
10-pin jumper at JP3. 
Dev i c e  Ma p p i ng   
Once the Monarch PMC module has completed initialization of the CC1000dm local 
bus, the PCI agents located on that bus are available for access. There are up to two PCI 
devices installed on the PLX PCI 6254 (HB6) secondary bus and two PCI IDSEL lines 
allocated to each PMC slot. 
 lists all the IDSEL mappings. 
3.3 Volts:
5 Volts:
3.3 and 5 Volts Combined:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
8.5 amps
6 amps
28-30 watts
PCI Address Line:
Local PCI Device IDSEL Connection:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AD22
PMC 1
AD21
PMC 1 Alternate Device
AD20
PMC 2
AD19
PMC 2 Alternate Device
AD18
PLX PCI 6254 (HB6) PCI Bridge
Table 3-1:                                                                                    
PMC Slots Available Power
Note:                                                                                    
A maximum load current of 6 
amps (worst case) results in a 
voltage drop of approximately 
100 mV to the PMC 5 volt 
power supply inputs. To ensure 
proper module operation, 
adjust the CompactPCI power 
supply to accommodate any 
voltage drop or power supply 
ripple that may occur when 
operating the carrier card.
Table 3-2:                                                                                    
IDSEL Mapping for PCI 
Devices