Emerson FM-3 Manuel D’Utilisation

Page de 292
23
Operational Overview
Example 3: If the starting position is 45° and 315° is the specified position, an Absolute 
index would travel  90° in the negative direction because that is the shortest path between 
45° and 315°.
Rotary Plus indexes will move to the specified position and are forced in a positive (or 
plus) direction.  Rotary Plus index distances must be within the rotary rollover range.
Example 4: As in example 2 above, the starting position is at 90° and 80° is the specified 
position.  A Rotary Plus index would travel 350° in the positive direction. At the 
completion of this index the motor position would be 80°.
Example 5: If the starting position is 10° and the specified position is 350°, a Rotary Plus 
index will travel 340° in the positive direction.
Rotary Minus indexes move to the specified position, but are forced to travel in the 
negative (or minus) direction.  Rotary Minus index positions must be within the rotary 
rollover range.
Example 6: As in examples 2 and 4 above, the starting position is at 90° and 80° is the 
specified position.  A Rotary Minus index would travel 10° in the negative direction. At 
the completion of this index the motor position would be 80°.
Example 7: If the starting position is 15° and the specified position is 270°, a Rotary 
Minus index would travel 105° in the negative direction.
How Communications Work
Uploading
Uploading is the process of reading information back from the drive to the PowerTools Pro 
configuration screens.  
To upload information from a drive, click on the upload button on the PowerTools Pro toolbar 
or select upload from the Device menu. 
Downloading
Downloading is the process of sending your configuration created with PowerTools Pro from 
the PC to the FM-3 module. Changes made in PowerTools Pro will not take effect until the 
information has been downloaded or the Update to RAM button has been clicked.
To download information to a FM-3, click on the download button on the PowerTools Pro 
toolbar or select download from the Device menu. PowerTools Pro will lead the user through 
a series of dialog boxes that determine what baudrate and which communications port on the 
user’s PC will be used.