Setting Up Parameters
Analog Inputs View
The FM-3 module is able to use the analog input circuitry located on the drive.  The analog 
input accepts a +10 to –10 Volt signal.  The analog input can be setup on the Analog view, 
which is located underneath the I/O Setup group in the PowerTools Pro hierarchy. 
 Figure 52:
Analog Inputs View
The drive has a 14-bit analog to digital converter (A/D) which is used to transform the analog 
voltage to a usable parameter in the FM-3 module.  The analog input is scanned every 100 
microseconds.  
 User Units
This parameter allows the user to enter a 12 character string to be used as units for the analog 
input parameter.
Decimal
This parameter defines how many digits (up to six) are used after the decimal place for the 
user unit scaled analog input parameter. This defines the maximum resolution of the analog 
input parameter.