 CTbus/SCbus Adapter  
Installation 
 
 
Part Number  
64-0010-02 
Copyright © 1997-2007 
Dialogic Corporation.  
All Rights Reserved. 
 
 
 
 
 
 
 
 
 
 
The Dialogic
®
 CTbus/SCbus Adapter is used to interconnect 
Dialogic
®
 CTbus boards with Dialogic
®
 SCbus boards in the 
same chassis.  Only one adapter is required per system. 
 
 
 
Before You Begin 
 
 Protect Yourself from Electric Shock 
The CTbus carries electrical signals. To reduce the risk 
of electric shock: 
  
Switch off the power and remove power cords 
before opening the PC cover. 
  
Do not re-attach power cords and switch on power 
to the PC while the PC cover is removed. 
  
 
 
Protect the Board from Damage 
 Protect the Board from Static Electricity 
CAUTION: All computer boards are sensitive to 
electrostatic discharge (“ESD”).  Handle all static-
sensitive boards and components at a static-safe work 
area, and observe anti-static precautions at all times. 
 
If you are not familiar with ESD safety precautions, visit 
 
Unpacking the Board 
Unpack the Dialogic
®
 CTbus/SCbus Adapter (“adapter”) 
according to the following steps: 
1. 
Prepare a static-safeguarded work area. 
2. 
Carefully remove the adapter from the shipping 
carton and the anti-static packaging.  Handle the 
adapter by the edges and avoid touching the 
components. 
3. 
Lay the adapter on the static-dissipative work 
surface. 
Note: Place the adapter in static-shielding bags when carrying 
it from station to station. 
CAUTION: Do not remove the adapter from the anti-
static packaging until you are ready to install it.  
Observe proper anti-static precautions at all times.
 
 
 
Installing the CTbus/SCbus Adapter
 
Before installing the CTbus/SCbus Adapter, ensure that the 
Dialogic
®
 boards in your chassis are positioned in the correct 
order.  The board on which the adapter will be installed must 
be inserted in the first PCI slot adjacent to the ISA slot (Figure 
1). 
 
Figure 1.  Board Order
 
To install the Dialogic
®
 CTbus/SCbus Adapter:
 
1. 
Locate the board that will be used to connect the 
CTbus/SCbus Adapter.  It will be the card inserted in the 
first PCI slot adjacent to the ISA slot. 
2. 
Align pin 1 of the CTbus/SCbus Adapter with pin 1 of the 
edge connector on the board (Figure 2).  NOTE: Edge 
connector is not labeled. 
 
Figure 2.  Adapter Alignment (D/41ESC-PCI shown) 
3. 
Press the CTbus/SCbus Adapter to the board (Figure 3). 
 
Figure 3.  Connect the Adapter (D/41ESC-PCI shown) 
4. 
Connect the CTbus and SCbus cables as per the 
installation instructions for your Dialogic
®
 board(s).