Quantum Audio STT2401A Manuel D’Utilisation

Page de 137
Chapter 5 
 
ATAPI Interface 
Page 112 
Seagate Travan 40 Product Manual 
 
STANDBY (ATA Command E2) 
This command is accepted but performs no function. This command causes the 
device to enter the Standby mode. 
If the Sector Count register is non-0, then the Standby timer shall be enabled. The 
value in the Sector Count register shall be used to determine the time programmed 
into the Standby timer. 
If the Sector Count register is 0, then the Standby timer is disabled. 
Host Taskfile Registers—Inputs 
 
Data Bits 
Host Taskfile 
Register 
HEX 
Features 
N/A 
N/A 
Sector Count 
Standby timer setting: 
 
00h           timeout disabled 
01h-F0h    timeout= (value * 5) sec 
F1h-FBh   timeout= ( (value-240) * 30) min 
FCh          timeout= 21 minutes 
FDh          timeout= period between 8 and 12 hours 
FEh          reserved 
FFh          timeout= 21 min 15 sec 
N/A 
Sector 
Number 
N/A 
N/A 
Byte Count 
High 
N/A 
N/A 
Byte Count 
Low 
N/A 
N/A 
Device/Head 
rsvd 
LBA 
rsvd 
DEV 
SAM LUN (not used) 
 
Command 
command 
E2 
Host Taskfile Registers—Outputs 
 
Data Bits 
Host Taskfile 
Register 
HEX 
Error 
rsvd 
tag type (not supported) 
MCH 
ABRT 
EOM 
ILI 
00 
Sector Count 
N/A 
N/A 
Sector 
Number 
N/A 
N/A 
Byte Count 
High 
N/A 
N/A 
Byte Count 
Low 
N/A 
N/A 
Device/Head 
rsvd 
LBA 
rsvd 
DEV 
SAM LUN (not used) 
 
Status 
BSY 
RDY 
rsvd 
DSC 
DRQ 
Corr 
rsvd 
CHK 
40 or 50