ATAPI Interface 
Chapter 5 
Seagate Travan 40 Product Manual 
Page 39 
 
 
Parameter Code 
LSB 
 
01 
DU 
DS 
TSD 
ETC 
TMC 
LP 
40 
Parameter Length 
04 
10 
11 
12 
13 
MSB 
Total Errors Corrected 
LSB 
XX 
XX 
XX 
XX 
NOTE: (Total Blocks Recovered by ECC) + Total Errors Corrected = Total Blocks Read 
Page 03—Error Counter for READ definitions 
Byte 
 
 
00 
Page Code  
Set to 03h. 
01  
Reserved 
Set to 00h. 
02-03 
Additional Page Length 
Set to 1Ch. 
04-05 
Parameter Code 
0000h—# of block recovered by ECC alone 
0001h—# of blocks recovered without using ECC 
0002h—total # of rereads 
0003h—total errors corrected 
0004h—# of frames corrected by ECC alone 
0005h—total # of bytes processed 
8004h—total # of bytes corrected by ECC 
06 
DU 
The Disable Update bit is always set to 0, indicating the drive 
updates parameter values for all events. 
 
DS 
The Disable Save bit is always set to 1, indicating the drive 
does not save parameter values. 
 
TSD 
The Target Save Disable bit is always set to 0 indicating the 
drive defines a method for saving log parameters. 
 
ETC 
The Enable Threshold Comparison bit is always set to 0, 
indicating comparison to the threshold value is not performed 
whenever the cumulative value is updated. 
 
TMC 
The Threshold Met Criteria bits are used with the ETC bit and 
are always set to 0. 
 
LP 
The List Parameters bit is always set to 0, indicating all 
parameters are data counters. 
07 
Parameter Length 
Set to 02h, indicating 2 bytes in the counter. 
08-09 
Total Re-Reads 
(*)
 
Total number of uncorrectable frames. An uncorrectable 
frame will generate a Re-Read recovery sequence. 
… 
 
 
0E-10 
Total Errors Corrected 
(*)
 
Total number of frames corrected is the sum of the number of 
frames corrected by ECC plus the number of frames corrected 
by the Re-Read recovery procedure. 
… 
 
 
15-16 
Frames Corrected By 
ECC Alone 
(*)
 
The total number of frames containing one or more blocks that 
failed the CRC check. For the total number of blocks, see 
REQUEST SENSE. 
… 
 
 
1B-1F 
Total Bytes Processed 
(*)
 
The transfer length of all Fixed Block Mode READ commands 
times the block length specified in Mode Data plus the total 
transfer length of all Variable Block Mode READ commands. 
… 
 
 
1B-1F 
Total Bytes Corrected 
by ECC 
(*)
 
The total number of bytes corrected by ECC during all READ 
commands.