RAD Data comm RIC-155 Manuel D’Utilisation

Page de 90
Appendix B  Traffic Separation 
RIC-155 Installation and Operation Manual 
B-8 
Configuring for a Typical Application 
 
MNG 1
1
2
2
1
1
1
1
Local RIC-155
Switch
Remote RIC-155
2
2
2
2
Host
Host
Uplink
Uplink
Data
Management
Station
LAN
LAN
Data
 
Figure B-10.  Managing RIC-155 via Data Port 
The units are configured as follows: 
•  Local RIC-155: 
 
Forwarding – Filter Tagged 
 
Port Management Access – All 
 
Host Tagging – Tagged 
 
Host VLAN – 1 
 
Host VLAN Priority – any from 0 to 7 
 
Management and data ports – Tag stripping is disabled 
 
Uplink port – Tag. 
•  Remote RIC-155: 
 
Forwarding – Filter Tagged 
 
Port Management Access – None 
 
Host Tagging – Untagged 
 
Management and data ports – Tag stripping is enabled 
 
Uplink port – Stack.