Quantum Audio A-Series Manuel D’Utilisation

Page de 105
Chapter 2  Getting Started
Resetting System Defaults
Quantum A-Series Tape Drives User’s Guide
8
SDLT 600A Drive Reset
2
To reset an SDLT 600A tape drive back to default values: 
1
Disconnect the network cable from the drive.
2
Switch off your tape drive.
3
Insert a write protected cartridge into the drive.
4
Switch on the tape drive (after approximately one minute, the 
cartridge will be ejected).
5
Repeat steps 2 – 4 above two more times.
6
After the third cycle, switch off your tape drive.
7
Reconnect your network cable and switch on the tape drive.
8
Set your cartridge write protection on or off (as you need it) and 
reinsert the tape (or another tape).
9
Access the drive from a browser at the default IP address 
(10.10.10.10) to reconfigure to your desired settings.
LTO-3A Drive Reset
2
To reset an LTO-3A tape drive back to default values:
1
Disconnect the network cable from the drive.
2
Insert a write protected cartridge into the drive (wait approximately 
30 seconds for tape to load and lights to stop flashing).
3
Switch off your tape drive for 10 seconds.
4
Switch on the tape drive (after approximately three minutes, the 
cartridge will be ejected and reloaded; after an additional 30 seconds 
lights will stop flashing).
5
Repeat steps 2 – 4 above two more times.
6
After the third cycle, press the eject button on the drive to eject the 
tape and switch off the drive.
7
Reconnect your network cable and switch on the tape drive.
8
Set your cartridge write protection on or off (as you need it) and 
reinsert the tape (or another tape).
9
Access the drive from a browser at the default IP address 
(10.10.10.10) to reconfigure to your desired settings.