Quantum Audio A-Series Manuel D’Utilisation

Page de 105
Functional Specifications
Quantum A-Series Tape Drives User’s Guide
39
Max for 
SDLT 600A tape 
drive Modes
9
N/A
3.8
N/A
N/A
2.1
N/A
N/A
3.8
N/A
N/A
1.
The Max-Peak value represents short current spikes drawn for durations of < 50ms. On the 12V supply, the 
peaks correspond to the pulse-width-modulated switching of the motors. These values are calculated from the 
average of Peak-ripple-current + 2 sigma, measured at nominal DC voltage.
2.
The Max-Mean value is the average of the maximum RMS current drawn during this operating mode. These 
values are calculated from the average of RMS current + 3 sigma, measured at nominal DC voltage.
3.
The typical current is calculated from the average of all RMS current drawn during this operating mode, 
measured at nominal DC voltage.
4.  The Max DC power is calculated from the typical DC power + 3 sigma, measured at nominal DC voltage. This 
value takes into account that the peak currents on the 5V and 12V do not occur at the same time.
5.
The Typical DC power is calculated from the average RMS DC power drawn during this operating mode, 
measured at nominal DC voltage. This value also takes into account that the peak currents on the 5V and 12V do 
not occur at the same time.
6.
The Max AC power is calculated from the typical AC power in tabletop tape drives + 3 sigma.
7.
The Typical AC power is calculated from the average of AC power drawn in tabletop tape drives.
8.
These events last < 1 second and occur at a duty cycle of less than 25%.
9.
The Max values for each mode are based on the Max-Mean values, since the peak values are of very short 
duration.
(Common Notes)
(1) Voltage tolerance: 5V ±5%, 12V ±5%; Room temperature 24 °C. AC power measured at 117 V, 60 Hz.
(2) DC Current, MaxMean, and DC/AC Power Max refer to the statistically calculated maximum average 
requirement based on a sample population of tape drives. These values do not reflect the peak current or power 
requirement; this amount is given by the DC MaxPk current.
(3) These results were from the DVT data taken by Percept Technology. Reference the “Power Consumption & 
Characterization Test Report” dated 11/28/2005.
(4) Test data set included 12 measurements: 3 measurements of 4 drives.
(5) The 5V “MaxPK” calculated to less than MaxRMS, which does not at first glance make sense. (MaxPK is 
calculated at 5.25V, and the switching power supplies need less input current to the same input current.) 
Instead, the MaxRMS value was substituted.
Mode
5 V Current (A)
MaxPk
1
MaxMean
2
Typ
3
12 V Current (A)
MaxPk
1
MaxMean
2
Typ
3
DC Power (W)
Max
4
Typ
5
AC Power (W)
Max
6
Typ
7