Quantum Audio A-Series Manuel D’Utilisation
Recording Media Specifications
Quantum A-Series Tape Drives User’s Guide
45
Media Shipping,
Operating, and Storage
Specifications
Operating, and Storage
Specifications
1
The optimum media shipping conditions are described in
.
Figure 13 Super DLTtape II
Media Shipping Limits
Media Shipping Limits
Table 17 Super DLTtape II
Media Operating Limits
Media Operating Limits
describes the optimum media storage conditions.
Table 18 Super DLTtape II
Media Storage Limits
(Continued)
Media Storage Limits
(Continued)
Shipping Conditions
Temperature
–18 °C to 49 °C (0 °F to 120 °F)
Relative Humidity
20 to 80% (non-condensing)
Maximum Wet Bulb Temperature
26 °C (79 °F)
Maximum Dew Point
2 °C (36 °F)
Operating Conditions
Temperature
10 ° to 40 °C (50 ° to 104 °F)
Relative Humidity
20% to 80% (non-condensing)
Storage Conditions
Archival
Non Archival
Temperature
18 ° to 28 °C
(64 ° to 82 °F)
16 ° to 32 °C
(60 ° to 90 °F)
Relative Humidity
40% to60%
(non-condensing)
20% to 80%
(non-condensing)