Appendix E  Parameters and Screens 
IPmux-1/1E Installation and Operation Manual 
E-10 General 
Configuration 
 
 
The other alarms are not used.  
 
 
ASCII Terminal Configuration 
ASCII TERMINAL CONFIGURATION 
1. Display Mode        Color 
2. Baud Rate (bps)     19200  
3. Change Password 
4. 15 Min. Timeout     On 
 
ESC. Exit 
NOTICE:  Change the Baud Rate of the ASCII terminal after 
changing and saving of new Baud Rate data ! 
Select item from the menu:_ 
Use <Esc> key or keys <1> to <4>
 
Figure E-13.  ASCII Terminal Configuration Menu 
Table E-6.  ASCII Terminal Configuration Parameters 
Name Possible 
Values Remarks 
Display Mode 
Color 
MonoChrome 3 color 
MonoChrome 2 color 
 
 
Baud Rate 
9600, 19200, 38400, 57600, 
115200
 – in units of bps 
Default: 19200 bps 
Change Password 
 
Choose this option to enter a menu that allows the 
user to change the current password 
15 Min. Timeout 
On, Off 
On – terminal/Telnet exits to the password screen if 
no characters are sent by the terminal for 
15 minutes 
 
Main Menu 
         ↓ 
2. Configuration 
         ↓  
1. General 
Configuration 
        ↓ 
4. ASCII 
Terminal Config 
Note 