Appendix E  Parameters and Screens 
IPmux-1/1E Installation and Operation Manual 
E-14 
IPmux-1 E1/T1 Configuration 
 
➤ 
To overwrite the system and reconfigure it according to default settings: 
•  Type Y
IPmux-1 is reconfigured according to default settings. Following this, 
IPmux-1 performs an automatic Reset. 
 OR 
•  Type N to exit and return to the General Configuration menu. 
 
1.  Setting default parameters from an ASCII terminal erases all the configurations 
and optionally asks if you want to erase Host IP and Default Gateway 
Configuration. 
2.  Setting default parameters from Telnet or NMS does not erase the Host IP or 
Default Gateway Configuration. 
 
E.4  IPmux-1 E1/T1 Configuration 
E1 Configuration 
E1 CONFIGURATION 
1. Channel Status 
Enable 
2. Transmit Clock Source 
Adaptive 
3. Loopback State 
Disable 
4. Rx. Sensitivity 
-10dB 
5. Line Type   
CRC4 enable 
6. Idle Code   
7E 
7. Signaling Mode 
CAS enable 
8. Cond. Data pattern 
FF 
9. Cond. CAS (ABCD)pattern 
01 
ESC. Exit 
 
Select item from the menu. 
Use <Esc> key or keys <1> to <9>
 
Figure E-19.  E1 Physical Layer Configuration Menu 
 
When “unframed” mode is selected, the Idle Code, Signaling Mode, Cond Data 
Pattern and Cond CAS Pattern fields are not present. 
When CAS Disabled is selected, the Cond CAS Pattern field is not present. 
 
Note 
Main Menu 
         ↓ 
2. Configuration 
         ↓  
2. E1/T1 
Configuration 
Note 