RAD Data comm IPmux-1E Manuel D’Utilisation

Page de 143
Chapter 1  Introduction 
IPmux-1/1E Installation and Operation Manual 
1-18  
 
Functional Description
 
 
Table 1-2.  Ethernet Frame Structure 
Field length (bytes) 
Field 
7 Preamble 
1  
SFD 
6 Destination 
MAC 
Address 
6 Source 
MAC 
Address 
2 Type 
1 Vers/HLEN 
1 Service 
Type 
2 Total 
Length 
2 Identification 
Flags/Fragment Offset (most) 
1 Fragment 
Offset 
(least) 
Time to Live 
1 Protocol 
2 Header 
Checksum 
Source IP Address 
4  
Destination IP Address 
UDP Source Port 
UDP Destination Port 
UDP Message Length 
2 UDP 
Checksum 
... Payload 
4 CRC 
 
VLAN Support 
VLAN, according to IEEE 802.1p&q, adds four bytes to the MAC layer of the 
Ethernet frame. The contents of these bytes, MAC layer priority and VLAN ID, can 
be set by the user. In this mode, only VLAN format frames are sent and received 
by IPmux-1. Figure 1-17 describes the VLAN tag format.  
MAC 
Layer 
IP Layer 
MAC 
Layer 
UDP 
Layer 
Data 
Layer 
LLC 
Layer 
Note: IEEE 802.1p&q VLAN 
Tagging (additional 4 bytes if 
enabled) 
Note: The UDP source port 
field is used to transfer the 
destination bundle number. 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com