RAD Data comm IPmux-1E Manuel D’Utilisation

Page de 143
Chapter 1  Introduction 
IPmux-1/1E Installation and Operation Manual 
1-24  
 
Technical Specifications
 
 
 
All of the above exist only in rate limiting mode, and do not exist in bridge mode. 
 
 
The bridge/rate limiter modes are selected by the rate limiter parameter. When set 
to 0 the bridge mode is selected, otherwise the rate limiter is selected by the 
specified rate. 
1.4 Technical Specifications 
E1 Port 
Compliance 
Connector 
 
 
Data Rate 
Line Code 
Line Impedance 
Signal Levels 
 
 
 
Jitter Performance 
External Adapter 
Cable 
ITU-T Rec. G.703, G.706, G.732, G.823 
Balanced: RJ-45 8-pin 
Unbalanced: TBNC 75Ω (an external adapter cable from 
TBNC to BNC is required) 
2.048 Mbps 
HDB3 
Balanced: 120Ω; Unbalanced: 75Ω 
Receive: 0 to –32 dB with LTU 
              0 to –10 dB without LTU 
Transmit Balanced: ±3V  ±10% 
Transmit Unbalanced: ±2.37V  ±10% 
ITU-T G.823 standard 
TBNC to BNC required 
 
 
 
E1 Framing 
Compliance 
Framing 
Signaling 
G.704, G.706 
Pass Through, CRC4 MF, CAS MF 
CAS, CCS (transparent) 
 
 
 
T1 Port 
Compliance 
Connector 
Data Rate 
Line Code 
Line Impedance 
Signal Levels 
 
 
 
Jitter Performance 
ANSI T1.403, ITU-T Rec. G.703, G.704 
RJ-45, 8-pin 
1.544 Mbps 
B8ZS, B7ZS, AMI 
Balanced: 100Ω 
Receive: 0 to –30 dB 
Transmit: 0 dB, –7.5 dB, –15 dB,  –22.5 dB, with CSU 
               ±2.7V ± 10%, adjustable, measured in range 
                0 to 655 feet, without CSU 
AT&T TR-62411, G.824 standards 
Note 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com