Chapter 5  Application Configuration Procedures 
IPmux-1/1E Installation and Operation Manual 
5-14 
Configuring the Management Option
 
 
8. Press <Esc> a few times to return to the Main menu. 
 
 
1.  Remember to press <Enter> after modifying each parameter. Press <S> to 
save all changes on the menu. 
2.  TDM Bytes in Frame and Jitter Buffer have been automatically set to default 
values: 48 for TDM Bytes, 3 ms for Jitter Buffer. 
 
 
BUNDLE CONNECTION CONFIGURATION 
 
1. Bundle ID 
 
32 
2. Connection State 
 
Enable 
3. Destination IP Address 
192.168.10.1 
4. Next Hop 
 
0.0.0.0 
5. Destination Bundle   
6. Jitter Buffer(x10usec) 
300 
 
ESC. Exit 
 
D. Delete 
N. Next 
 
Select item from the menu. 
 
Total used bundles: 1 
Figure 5-7.  Bundle Connection Configuration in IPmux-4 
5.4  Configuring the Management Option 
To configure this application for RADview or an SMNP management station 
perform the following steps on each station of IPmux-1 and IPmux-4.  
Authentication/Community 
➤ 
To configure Authentication/Community: 
1. From the Management Configuration menu, press 1 
Authentication/Community
 menu (see Figure 5-8). 
2.  Select Authentication Failure Trap and choose On. 
3. Select Trap and choose Public
4. Select Read and choose Public
5. Select Write and choose Public
6. Press <S> to save the configuration. 
7. Press <Esc> to return to the Management Configuration menu. 
Note 
Main Menu 
↓ 
2. Configuration 
↓ 
1. General 
Configuration 
↓ 
3. Management 
Configuration 
↓ 
1. 
Authentication/ 
Community
 