RAD Data comm IPmux-1 Manuel D’Utilisation

Page de 143
Chapter 5  Application Configuration Procedures 
IPmux-1/1E Installation and Operation Manual 
5-4 IPmux-1
 
 
•  Manage IPmux-1/4 by means of SNMP-based network management stations, 
e.g., the RADview network management station offered by RAD. 
Changing Parameters 
•  Use the <Spacebar> on your keyboard to toggle between options in the 
menus, and then save. 
•  Press <Enter> after entering a new parameter, such as the IP address, and 
then save by pressing S
•  At any point and from any screen, you can press <Esc> repeatedly, backing 
up until you reach the Main menu. 
Checking Connectivity 
After the configuration has been completed, several tests should be performed in 
order to verify proper connectivity. For testing procedures see Section 5.5
5.2 IPmux-1  
Powering-up 
➤ 
To turn on IPmux-1: 
1.  Make sure all IPmux-1 cables and connectors are properly connected. 
2.  Connect IPmux-1 to a PC equipped with an ASCII terminal-emulation 
application (for example, Windows 95 Hyper Terminal or Procomm). 
3.  Turn on the control-terminal PC and set its default port parameters to  
19,200 baud, 8 bits/character, No Parity, 1 stop bit.
  
4.  Set the terminal emulator to ANSI VT100 emulation (for optimal view of 
system menus).  
5.  Switch ON the POWER supply switch, located on the rear panel. 
When the initialization and self-test are over, a menu appears displaying 
initialization and self-test results. If the self-test is successful, the RDY LED 
on the left side of the front panel lights up.  
➤ 
To logon: 
1. Press <Esc> to open the configuration software. 
2.  Enter your User Name as Supervisor (su) and press <Enter>. 
3.  Enter your Password (the factory-set password is xxxxxxxxxx).  
 
 
If the password is invalid in three consecutive attempts, the system becomes 
inaccessible for 15 minutes. 
 
 
Note 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com