RAD Data comm ASMi-31 Manuel D’Utilisation

Page de 66
ASMi-31 Installation and Operation Manual 
Chapter 1.  Introduction
16-03-00 15:51
Technical Specifications
1-5
1.4   Technical Specifications
Line Interface
Type
2-wire, full duplex unconditioned telephone
line (twisted pair), using echo-cancellation
Line Coding
2B1Q
Range
Up to 8 km (5 miles), over a 24 AWG wire,
independent of data rate
Level
Up to 14 dBm (assuming a 135Ω load)
Connector Type
3-clip terminal block and RJ-45 connector
Standard
Complies with ANSI T1.601.1988
specifications
Digital Interface
(DTE)
Types
ITU V.24/RS-232, V.35, RS-530 or X.21,
G.703 Codirectional (64 kbps),
Ethernet (10BT), Ethernet 10B2 (BNC)
Data Rates
1.2 kbps to 128 kbps
Connectors
• 
V.24 – 25-pin, D-type female
• 
V.35 – 34-pin, female
• 
V.36 – 37-pin, D-type female, via supplied
cable adapter
• 
X.21 – 15-pin, D-type female
• 
RS-530 – 25-pin, D-type female
• 
G.703/TB – Terminal Block
• 
G.703/RJ – RJ-45, female
• 
Ethernet (10BaseT) – RJ-45, conforms to
IEEE 802.3
• 
Ethernet (10Base2) – BNC
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610