Chapter 2.  Installation and Setup
ASMi-31
 Installation and Operation Manual
2-2
Installation and Setup
16-05-01 13:37
2.2   Package Contents
• 
One ASMi-31 unit (protected by adequate cushioning)
• 
AC power cord or DC power supply connector kit
• 
ASMi-31 Installation and Operation Manual
• 
Interface adapter cable(s) (see Table 2-2) - Optional.
2.3   Installation and Setup
ASMi-31 is a standalone device intended for tabletop or bench installation.
It is delivered completely assembled. No provisions are made for bolting
ASMi-31 to the tabletop. For installation of the unit in a 19" rack, refer to
Appendix F.
➤ 
➤ 
➤ 
➤  To complete the installation of ASMi 31:
1. Determine the required configuration of the modem according to your
application, and set the internal jumpers and switches accordingly (see
and .
2. Connect the line (see Connecting the Line below).
3. Connect the DTE interface (see Connecting the DTE below).
4. Connect power to the unit (see Connecting the Power below).
Setting the
Internal Jumpers
This section provides information on the functions of the internal jumpers
and switches, to help you in the selection of the correct settings for
particular application, and gives you step-by-step instructions for
performing the internal settings. The default settings are also listed.
1. Open the ASMi-31 case.
2. Set the ASMi-31 internal jumpers and switches, referring to Figure 2-1
and Table 2-1.
3. Reinstall the ASMi-31 cover.