RAD Data comm ASMi-31 Manuel D’Utilisation

Page de 66
ASMi-31 
Installation and Operation Manual 
Appendix A.  Ethernet Interface
Installation and Operation
A-3
When using the RJ-45 connector, the customer must prepare a mechanical
cable for adapting the DB-25 pinout to that of RJ-45. The pinouts of the
DB-25 and RJ-45 connectors are given in Table A-1.
Table A-1  DB-25 and RJ-45 Pin Assignment for IR-ETH Connection
Signal
Pin
DB-25
RJ-45
RCV (+)
13
3
RCV (-)
12
6
XMT (+)
11
1
XMT (-)
9
2
GND
7
-
A.4   Ethernet Bridge Specifications
General
LAN Table
10,000 addresses
Filtering and
Forwarding
15,000 pps
Buffer
256 frames
Delay
1 frame
LAN
Standard
Conforms to IEEE 802.3/Ethernet
Data Rate
10 Mbps (20 Mbps 10BaseT FDX)
Connectors
10BaseT (UTP): Shielded RJ-45
10Base2: BNC connector
WAN
Protocol
HDLC
Data Rate
According to the modem transmission rate
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com