Configuring the V.35 data port
Configuring the Z-Plex
user>
 
SET FX0CFG:TS:2:7-15
5. Specify the FXO type:
user>
 
SET FX0CFG:TYPE:2:LS
6. Specify whether you want the Z-Plex unit to provide ringback. For example:
user>
 
SET FXOCFG:RNGBK:2:ON
The default of OFF is appropriate for cases when the network service does not provide an 
audible ringing tone to the calling party. 
7. Specify whether trunk conditioning is being used:
user>
 
SET FX0CFG:TRNKC:2:ON
8. Specify the Transmit TLP setting, which controls the amount of gain or loss added to a 
voice signal from the CPE before it is encoded to digital PCM. 
user>
 
SET FX0CFG:TTLP:2:-3
9. Specify the Receive Transmission Level Point (TLP), which controls the amount of gain 
or loss added to the incoming signal after it is decoded to analog. For example:
user>
 
SET FX0CFG:RTLP:2:-8
10. Activate the port:
user> SET FX0CFG:STATE:2:ACTIVE
4.8
Configuring the V.35 data port
The Z-Plex unit uses the V.35 port to interface directly with Data Service Units/Channel 
Service Units (DSU/CSUs) supporting data traffic up to and including 64 kbps. A four-wire 
circuit can connect the V.35 port to a DSU/CSU up to four miles away. In the switched 56 kbps 
mode, customers access the network on an as-needed basis via dial-up commands. The system 
must be equipped to provide -48 VDC power to fully support the V.35 port. 
The following is an example of configuring the V.35 port:
1. Specify the data rate of the port:
user>
 
SET DPCFG:RATE:1:64K
2. Specify the clocking for the port:
user>
 
SET DPCFG:CLK:1:NORMAL