Quantum Audio Scalar 50 Manuel D’Utilisation

Page de 24
Quantum Scalar 50 Tape Drive Installation Instructions
Document 81-81769-01 B01
September 2007
18
Completing the Native Fibre Channel Installation
Figure 20  Tape Drive 
Configuration Screen
7
Record the WWNs for the media changer and tape drives in 
.
• Repeat 
 for all tape drives in the library
or
• Add 
04h
 to the last hex byte to derive the WWN for the next tape 
drive. 
Example: 
Drive 0
 WWN is 50:05:08:40:16:6B:
00
Drive 1
 WWN will be 
50:05:08:40:16:6B:
04
Drive 2
 WWN will be 50:05:08:40:16:6B:
08
.
8
To determine the WWN for the media changer, subtract 
01h
 from the next 
to last hex byte of the WWN for 
Drive 0
Example: 
Drive 0
 WWN is 50:05:08:40:16:
6B
:00, 
Media Changer
 WWN will 
be 50:05:08:40:16:
6A
:00.
Verifying Library 
Connectivity
0
To verify the tape drive installation, you should verify that the library and 
tape drives are recognized from the host or from the SAN switch.
If the SAN switch is available, it is possible to verify connectivity by 
connecting to the switch. There are two ways to directly access the SAN 
switch:
Note:
These numbers are the world wide NODE names for the 
library and tape drives. The World Wide Port Name is very 
similar to the World Wide Node Name, however, the last hex 
byte is 01h greater than the last hex byte of the node name.
World wide names 