Quantum Audio Scalar 50 Manuel D’Utilisation

Page de 24
Quantum Scalar 50 Tape Drive Installation Instructions
Document 81-81769-01 B01
September 2007
Fibre Channel Connectivity Troubleshooting
21
e
If you are still unable to view the Fibre Channel devices, launch the 
SANsurfer SANblade manager and click Connect. Accept the default 
“localhost” entry.
The SANblade manager displays (see 
Figure 22  SANblade 
Manager
The SANblade manager should display all connected Fibre Channel 
devices. If the library and tape drives do NOT display, check the 
cabling and connection status. 
SCSI ID Assignment 
with Native Fibre 
Channel Tape Drives
0
With native Fibre Channel tape drives, each tape drive is it’s own Fibre 
Channel target with a dedicated WWN and on LUN 0. The host (including 
the laptop using MAGMA box) will pick up the devices and assign local SCSI 
IDs in the order that the SAN devices are discovered. This will in almost 
every case NOT match the order of the devices as they are installed in the 
library. This is not a problem from the customer point of view, as long as 
drive serialization is enabled on the library and serialization is supported by 
the customers ISV application. This will allow the ISV application to put the 
drives in the correct order within the application. 
In some rare cases it may be necessary to re-map the local SCSI ID 
assignments so that the library changer is at SCSI ID 0 and the drive SCSI ID 
assignments follow in order. The important thing to remember is that the 
order of the SCSI IDs on your system will probably not match the order of the 
drives in the library. Make sure to check the SCSI ID that is assigned to the 
WWN of the drive you want to communicate with or you may be 
communicating to the wrong drive