Grandstream Networks GXW-410xv Manuel D’Utilisation

Page de 30
H
ARDWARE 
S
PECIFICATION
 
T
ABLE 
4:
  
H
ARDWARE 
S
PECIFICATION OF 
GXW-410
XV 
 
LAN interface 
2xRJ45 10/100Mbps 
LED 
8 LEDs  (GREEN) 
Universal Switching 
Power Adaptor 
Input: 100-240V AC, 50/60Hz, 0.5A Max 
Output: 12V DC, 1.25A 
UL certified  
Dimension 
225mm (L) x 172mm (W) x 42mm (H) 
Weight 
0.29 lbs (3.5 oz) 
Temperature 
32~104°F  
0~40°C 
Humidity 
10% - 90% (non-condensing) 
Compliance 
 FCC, CE 
 
C
ONFIGURATION 
G
UIDE
 
C
ONFIGURATION WITH 
W
EB 
B
ROWSER
 
The GXW-410xv has an embedded Web server that will respond to HTTP GET/POST requests. It also 
has embedded HTML pages that allow a user to configure the IP phone through any common web 
browser.  Examples of GUI interfaces can be downloaded @
 
 
 
A
CCESSING THE 
W
EB 
C
ONFIGURATION 
M
ENU
 
1.  Connect the Power to the GXW-410xv unit. 
2.  Connect an Ethernet cable between the LAN port on GXW-410xv to your PC. 
3.  You will have to assign a dummy IP with the same subnet as the GXW IP Address, which is 
192.168.0.160 by default. So, set an IP address like 192.168.0.x for your PC. 
4.  Launch web browser and type 
 at address of web browser. This connects you 
to the GXW-410xv web server. 
 
You may choose to use DHCP or PPPoE connection or another static IP address according to your local 
network environment. 
 
The Gateway Web Configuration Menu can be then accessed by the following URI: 
where the Gateway-IP-Address is the IP address of the Gateway.  
 
NOTE:  
To access the configuration page, type the GXW  IP address into the browser, stripping out the 
leading “0”  because the browser will parse in octet.
 e.g. if the IP address is: 192.168.001.014, please 
type in: 192.168.1.14.  
Grandstream Networks, Inc. 
GXW-410xv User’s Manual 
Page 11 of 30  
 
Firmware 1.0.0.36 
Updated:  11/2006