Chapter 4  Testing and Diagnostics 
 
Troubleshooting Instructions 
4-3 
4.3 Troubleshooting Instructions 
provides troubleshooting details. Perform the actions listed under 
Corrective Measures in the order given in the table, until the problem is corrected.
 
Table 4-2.  Troubleshooting Chart 
Symptom 
Probable Cause(s) 
Corrective Measures 
No AC power 
 
Verify that the power outlet is providing the required power. 
Ensure that both ends of the AC power cord are connected 
properly. 
PWR LED is 
OFF 
Blown fuse 
Replace with fuse of proper rating. 
One of the four wires is 
disconnected from the DB-15 
connector of FOM-E1/T1 
Ensure all the wires are connected properly to the DB-15 
connector. 
 
One of coaxial cables is 
disconnected or defective 
Ensure that both ends of the coaxial cables are connected 
properly and that the cables operate properly. 
The attached equipment 
outputs are not according to 
G.703 electrical levels 
Check that the output levels of equipment attached to  
FOM-E1/T1 comply with G.703 electrical levels. 
ELECTRICAL 
LOW LED is 
ON 
The SW1, SW2 switches are 
set incorrectly 
Verify that the SW1, SW2 switch positions correspond to the 
E1/T1 interface type
.
 
ELECTRICAL 
AIS LED is ON 
The attached equipment is 
transmitting “All 1s" string 
Ensure that the equipment attached to the FOM-E1/T1 
transmits real data (not “all 1s"). 
No optical connection. 
Ensure that both transmit and receive fiber connections on 
the local and remote units are connected properly. 
OPTICAL ERR 
LED is ON 
Optical budget is too low 
Measure the optical loss over the fiber link and verify that it 
meets the product specifications. 
The equipment attached to 
the remote unit is transmitting 
“All 1s" string 
Check the remote attached equipment transmission. 
OPTICAL AIS 
LED is ON 
The remote unit detected 
Electrical Low alert 
Check the remote unit and the remote attached equipment 
for possible fault.