Section 18   Multi-Function Timer Pulse Unit (MTU) 
 
 
Rev. 4.00  Sep. 14, 2005  Page 569 of 982 
 
 REJ09B0023-0400 
Example of Synchronous Operation Setting Procedure: Figure 18.11 shows an example of the 
synchronous operation setting procedure. 
No
Yes
Set synchronous
operation
<Synchronous presetting>
<Counter clearing>
<Synchronous clearing>
Clearing
source generation
channel?
Select counter
clearing source
Start count
Set synchronous
counter clearing
Start count
[1]
[3]
[5]
[4]
[5]
[2]
Synchronous operation
selection
[1]  Set to 1 the SYNC bits in TSYR corresponding to the channels to be designated for synchronous operation.
[2]  When the TCNT counter of any of the channels designated for synchronous operation is written to, the same value 
is simultaneously written to the other TCNT counters.
[3]  Use bits CCLR2 to CCLR0 in TCR to specify TCNT clearing by input capture/output compare, etc.
[4]  Use bits CCLR2 to CCLR0 in TCR to designate synchronous clearing for the counter clearing source.
[5]  Set to 1 the CST bits in TSTR for the relevant channels, to start the count operation.
Set TCNT
Synchronous presetting
Synchronous clearing
 
Figure 18.11   Example of Synchronous Operation Setting Procedure