Renesas SH7641 Manuel D’Utilisation

Page de 1036
Section 21   A/D Converter 
 
 
Rev. 4.00  Sep. 14, 2005  Page 803 of 982 
 
 REJ09B0023-0400 
Bit Bit 
Name 
Initial 
Value R/W Description 
10 to 8 
 All 
Reserved 
These bits are always read as 0. The write value should 
always be 0. 
CKS1 
CKS0 
R/W 
R/W 
Clock Select 
Selects the A/D conversion time. Clear the ADST bit  
to 0 before changing the conversion time. 
00: Conversion time = 151 states (maximum)  
clock = P
φ/4 
01: Conversion time = 285 states (maximum)  
clock = P
φ/8 
10: Conversion time = 545 states (maximum)  
clock = P
φ/16 
11: Reserved 
MULTI1 
MULTI0 
R/W 
R/W 
These bits select single mode, multi mode, or scan 
mode. 
00: Single mode 
01: Reserved (setting prohibited) 
10: Multi mode 
11: Scan mode 
3, 2 
 All 
Reserved 
These bits are always read as 0. The write value should 
always be 0.