Renesas SH7641 Manuel D’Utilisation

Page de 1036
Section 25   Electrical Characteristics 
 
 
Rev. 4.00  Sep. 14, 2005  Page 923 of 982 
 
 REJ09B0023-0400 
25.3.3 
AC Bus Timing 
Table 25.8  Bus Timing 
Conditions:  Clock mode 2/6/7, V
CC
= 3.0 V to 3.6 V, V
SS
Q = 0 V, Ta 
= −40°C to +85°C 
 
 
B
φ
 = 50 MHz
*
 
 
 
Item Symbol 
Min. 
Max. 
Unit 
Figure(s) 
Address delay time 1 
t
AD1
 
12 
ns 
25.13 to 25.39 
Address delay time 2 
t
AD2
 1/2t
cyc
 1/2t
cyc
 + 12 
ns 
25.22 
Address delay time 3 
t
AD3
 1/2t
cyc
 1/2t
cyc
 + 12 
ns 
25.40, 25.41 
Address setup time 
t
AS
 
— 
ns 
25.13 to 25.18 
Address hold time 
t
AH
 
— 
ns 
25.13 to 25.17 
BS delay time 
t
BSD
 
— 
12 
ns 
25.13 to 25.36 
CS delay time 1 
t
CSD1
 
12 
ns 
25.13 to 25.39 
CS delay time 2 
t
CSD2
 1/2t
cyc
 1/2t
cyc
 + 12 
ns 
25.40, 25.41 
Read write delay time 1 
t
RWD1
 
12 
ns 
25.13 to 25.39 
Read write delay time 2 
t
RWD2
 1/2t
cyc
 1/2t
cyc
 + 12 
ns 
25.40, 25.41 
Read strobe delay time 
t
RSD
 1/2t
cyc
  
1/2t
cyc
 + 12 
ns 
25.13 to 25.18, 
25.20 to 25.22 
Read data setup time 1 
t
RDS1
 1/2t
cyc
+ 8 
— 
ns 
25.13 to 25.18, 
25.20, 25.21 
Read data setup time 2 
t
RDS2
 
— 
ns 
25.23 to 25.26, 
25.31 to 25.33 
Read data setup time 3 
t
RDS3
 1/2t
cyc
 + 8 
— 
ns 
25.22 
Read data setup time 4 
t
RDS4
 1/2t
cyc
 + 8 
— 
ns 
25.40 
Read data hold time 1 
t
RDH1
 
— 
ns 
25.13 to 25.18, 
25.20 
Read data hold time 2 
t
RDH2
 
— 
ns 
25.23 to 25.26, 
25.31 to 25.33 
Read data hold time 3 
t
RDH3
 0 
— 
ns 25.22 
Read data hold time 4 
t
RDH4
 1/2t
cyc 
+ 5 
— 
ns 
25.40 
Write enable delay time 1 
t
WED1
 1/2t
cyc
  
1/2t
cyc
 + 12 
ns 
25.13 to 25.18, 
25.20 
Write enable delay time 2 
t
WED2
 — 
12 