-File Offset is subtracted from addresses from the file downloaded to the 
programmer.  For example, if you set File Offset to 1000h, then the downloaded 
data minus 1000h would be placed into the buffer at the address specified by the 
Buffer Start Address. 
-Buffer Start Address is the address in the buffer where you want your 
downloaded data to start.  For example, if you set Buffer Start Address to 800h, 
then the downloaded data only appears in the buffer beginning at address 800h. 
 
File Save 
                                          These addresses will be applied for programming the buffer data.    
-Buffer Start: Starting address for data to be saved. 
-Buffer End: Ending address for data to be saved. 
Config Option / Auto Inc 
 
The feature allows users to program a certain area that might contain a serial 
number in the memory device with serialized number by a certain value. 
Start: Start address of memory that contains serialized data 
End: End address of memory