JDS Uniphase MTS-6000 Fascicule

Page de 1
NORTH AMERICA
TOLL FREE: 1 866 228 3762
FAX: +1 301 353 9216
LATIN AMERICA
TEL:+55 11 5503 3800
FAX:+55 11 5505 1598
ASIA PACIFIC
TEL:+852 2892 0990
FAX:+852 2892 0770
EMEA
TEL:+49 7121 86 2222
FAX:+49 7121 86 1222
WEBSITE
:www.jdsu.com
CONNECTION-CHECKER.1206.SS.FOP.TM.AE
Test & Measurement Regional Sales
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS
MTS-6000 and MTS-8000 Optical Test Platforms
Connection Checker Promotion
Purchase a MTS-6000 Compact Optical Test Platform or a MTS-8000 Scalable Opti-
cal Test Platform and get 50% discount on these combinations below: 
•Visual Fault Locator (VFL) & Power Meter 
•Visual Fault Locator (VFL) & Optical Loss Test Set with Talk Set (LTS/TS) 
- Dual wavelength
•Visual Fault Locator (VFL) & Optical Loss Test Set with Talk Set (LTS/TS) 
– Triple wavelength
JDSU’s MTS-8000 and MTS-6000’s built-in “connection check” functions meet the 
technicians demands in offering faster time to test, higher measurement reliability, quick 
troubleshooting, as well as permanent availability.
VFL: 
Mandatory tool for any technician dealing with fiber patchcords and launch cables, 
the built-in visible light source allows for quick fiber continuity checks and visual break 
location, without the need of additional tools.
Optical Power Meter: 
Essential tool for quick power level measurement on live fiber, 
the built-in power meter keeps the instrument on line, without the use of additional test 
equipment. 
Loss Test Set/Talk Set: 
The built-in talk set option allows communication between both 
ends of the fiber while the test is running. The user can also send commands or transfer 
results to the product at the other end for immediate comparison or remote control. 
A data transfer function allows immediate far end results and performs bi-directional 
OTDR analysis.
A power meter and a light source are necessary for attenuation (insertion loss) measure-
ment on fiber links. The built-in loss test set option allows for the measurement of end to 
end loss without the need of other instruments.
Connection Check =
•Connector & patch panel inspection
•Continuity check
•Patch cord connectivity
•End to end loss
Highlights
• Built-in functions for permanent 
availability
• Quick Jumper/Patchcord check with 
VFL
• Power Level Measurement with 
Optical Power Meter
• Communication  and transfer along 
the fiber with Talk set
Ordering information
E80VFL
VFL with UPP connector
E80PM 
Optical power meter with 
UPP connector (2.5 mm 
provided as standard)
E8026LTSTS 
Optical loss test set with 
talk set 1310/1550 nm
E8036LTSTS 
Optical loss test 
set with talk set 
1310/1550/1625 nm
For a limited time, save
50%