Acer 08P4100 Manuel D’Utilisation

Page de 100
Installing the Mylex Disk Array Controller as the Primary Windows 2000 Controller
4-4
PCI Disk Array Controller Drivers Manual
Installation Procedure 1:
Using eXtremeRAID 2000, eXtremeRAID 3000, 
AcceleRAID 160/170LP, AcceleRAID 170, or 
AcceleRAID 352
If you are about to install the eXtremeRAID 2000, eXtremeRAID 3000, 
AcceleRAID 160/170LP, AcceleRAID 170, or AcceleRAID 352, you must 
first determine if you are performing a primary or secondary installation. 
The differences between these installations are described as follows:
Primary (new) Installation
A primary installation is: 
• First time installation of Windows 2000 operating system, according to 
the Microsoft User manual, and
• Mylex PCI RAID controller is the bootable device, configured with 
RAID EzAssist. 
Secondary (new) Installation
A secondary new installation is: 
• First time installation of Windows 2000 operating system, according to 
the Microsoft User manual, and
• Mylex PCI RAID controller is added as a non-bootable device. 
• You should first install Windows 2000 onto a disk on an embedded 
SCSI or IDE controller or SCSI host bus adapter. Then go to 
“Performing a Secondary Installation” on page 4-7
Secondary (existing) Installation
A secondary existing installation is when:
• Windows 2000 operating system is already installed, and
• A Mylex PCI RAID controller has been added to your system as a non-
bootable device.