ADC Modem MM701G Manuel D’Utilisation

Page de 108
Managing DSL
32
MM701G User Manual
2
Configure the following parameters as supplied by your service provider:
3
Click
Apply,
then save changes using
Parameter
Description
Exec Mode
Select CPE or CO. For point-to-point connections, one modem must 
be configured for CPE and the other for CO. For all other applications, 
select CPE.
Standard
Select Annex A or Annex B (Default: Annex A). Annex A and Annex B 
are both transmission standards. Annex A is most often used in North 
America. Annex B is most often used in Europe.
Startup Margin
Select a value from 2 DB to 15 DB. Applies only to Rate-Adaptive mode 
(Default: 2 DB).
Power Backoff
Select Enable or Disable (Default: Enable).
Clock Offset
Do not change from factory-ship configuration.
Upstream Frame Sync Word
Do not change from factory-ship configuration.
Upstream Stuffbits
Do not change from factory-ship configuration.
Downstream Frame Sync Word
Do not change from factory-ship configuration.
Downstream Stuffbits
Do not change from factory-ship configuration.
Encoder Coefficient A
Do not change from factory-ship configuration.
Encoder Coefficient B
Do not change from factory-ship configuration.
Minimum Base Rate
Enter a value from 1 to 36 to select the minimum acceptable data rate 
in Rate-Adaptive mode. Rate is equal to N*64kbps, where N is the 
selected value (Default: 1).
Maximum Base Rate
Enter a value from 1 to 36 to select the maximum acceptable data rate 
in Rate-Adaptive mode. Rate is equal to N*64kbps, where N is the 
selected value (Default: 36).
Minimum Sub Rate
Enter 0 or 1 (Default: 0).
Maximum Sub Rate
Enter 0 or 1 (Default: 1).
Wire Pair Mode
Select Single or Two (Default: Single).
Asymmetric PSD
Select Disabled, 1544 kb, or 784 kb (Default: Disabled).
Bit Rate Mode
Select Adaptive Rate or Fixed Rate (Default: Adaptive Rate).
Test Bit Rate
Select a value from 72K to 2368K (Default: 2320K).
SNR Margin Limit
Enter a value from -64 to 63. Used to control the front panel LED. 
(Default: 4).